Resistive Touch Controller
Please see the general FAQs of PenMount resistive touch controllers below. If you can't find the answers you want below, please mail to us.
Please refer to the following link: https://www.amtouch.com.tw/en/support/support-004_04.html
Read morePlease adjust the controller switch to non-PNP device. Since all PenMount RS-232 controller devices are Non-PNP in Windows CE, normally the RTS signal of the RS-232 is not used. However, sometimes the operating...
Read moreYes. The PenMount Linux device driver supports screen rotation from driver version V2.3.0.15 onwards. Please make sure that the system is using XrandR module V1.2 for screen rotation.
Read morePenMount Linux Driver 4.0 and later support multiple monitors. Please follow the steps below to set up monitor mapping.1. Acquire monitor name:Please run xrandr and determine the proper monitor name. "VGA1"...
Read moreIf you use the ARM hardware platform, it utilizes Reduced Instruction Set Computing (RISC). Please contact us to fill out your company profile and sign a NDA. PenMount will provide the source code to allow...
Read morePlease check the following:1. Does the IRQ / IO address of COM3 conflict with other ports ?2. Does the COM port work correctly with other devices such as a serial mouse ?3. Is the COM port already occupied...
Read morePlease refer to calibration instructions in the readme of the driver files and conduct the calibration. If this still does not resolve your problem, please contact us.
Read moreYes. The PenMount Linux device driver supports mouse and button operating modes from V2.0 onward. Please set up the correct settings before installing the device driver. More information can be found in the readme.txt...
Read moreIf the system is running Xfree86, please modify the xf86config file. If the system is using Xorg, please modify the xorg.conf file. Please reference the sample settings in the readme file and modify the file...
Read more1. The PenMount Linux Driver matches the version of the Linux system (kernel, X Windows System version) 2. Read the readme file, and follow the instructions to install the driver. 3. Remember that commands...
Read moreThe PenMount Linux device driver V2.3.0.15 and V2.4.1 will first backup /etc/X11/xorg.conf during installation and then overwrite it with PenMount specific settings to ensure that the touch screen operates...
Read moreThe reason that touch input continues to function after unplugging and reconnecting the PenMount USB device or switching USB ports, is because the Linux inbox HID driver is driving the PenMount USB device...
Read moreAll PenMount Linux drivers must be used on X window. If your Linux operating system uses another graphical interface or no graphical interface such as QT Linux, embedded Linux, mini GUI, or Micro windows,...
Read moreYes. If you are using Windows XP Tablet PC Edition 2005 / Windows Vista or Windows 7, you will be able to use tablet PC features such as press and hold for right mouse button, hand writing, and flicks...
Read moreThe PenMount Windows Universal Driver relies on the Windows HID driver. Please add Windows HID components into the XPE system when building. When you install the PenMount Windows Universal Driver, the system...
Read moreYes. The PenMount device driver can support Windows Embedded systems based on the Windows XP kernel including Windows XP Embedded and the Windows Embedded Standard 2009. There are two ways to install the driver:1....
Read morePlease first build the PenMount Driver sub project, then try to build the system image again.
Read more1. In Windows 2000 / XP, please press "s" to skip mapping when PenMount Control Panel prompts to map monitors without touch functionality. 2. On Windows 7, If the touch screen is mapped to monitors other...
Read moreNo. Currently users need to map the touch panel manually each time the extended desktop settings are changed.
Read more1. If the driver installed is not a PenMount Windows Universal Driver or an Universal Driver version earlier than 2.1, user must first remove the existing PenMount driver, connect new PenMount control...
Read morePenMount can support up to 6 touch controllers mapped to different display monitors simultaneously, with the following conditions: A. Please use Windows 2000 / XP / 7. (Windows Vista not supported) B....
Read moreYes, please refer to the following command to directly call the calibration program from the command line: <Path To Install Dir>DmcCtrl.exe -calibration [ 0 | 4 | 9 | 16 | 25 ] In this case, 0 is for standard...
Read moreCalibration is needed if the PenMount driver is being installed for the first time. The calibration utility has two modes: standard calibration and advanced calibration. Advanced calibration is used to correct...
Read moreIn Windows 2000 / XP / 2003, PenMount Windows Universal Drivers support the display rotation function of Intel, Nvidia, ATI, SMI, Via, and the Pivot rotation software by Portrait. In Windows Vista / 7 / 8 / 10, rotation...
Read moreFor PenMount Windows Universal Drivers before V2.1.0.263, please change the "Double click speed" of mouse, which can be found in the control panel.For PenMount Windows Universal Driver after V2.2.0.283,...
Read moreYes. The PenMount Windows Universal Driver has obtained Microsoft WHQL certification. If you need to use a driver that is certified WHQL, please download drivers labeled WHQL in the PenMount website.
Read more1. Uninstall the driver, making sure that the PenMount control board is connected to the computer, then restart Windows. 2. Make sure that the driver matches the PenMount control board and operating system...
Read moreIf you wish to install PenMount Universal Driver V2.0.0.113, please follow the steps below: 1. Download the appropriate PenMount Windows Universal Driver matching your operating system. 2. Uninstall the old PenMount...
Read moreGesture is a common word for finger or hand motion.Flicks are gestures that are used in Microsoft Vista. According to Windows SDK documents from Microsoft, "A flick is a unidirectional pen gesture that...
Read more1. Windows 7 supports multi-touch input devices, and provides API for two finger gestures. Windows Vista only supports single touch input devices. 2. On both Windows Vista and Windows 7, user will be able...
Read moreThe PenMount Windows Universal Driver V2.1.0.234 or later versions support Non-PnP RS-232 PenMount controllers. V2.1.0.234 will automatically change every COM port settings to allow detection of PenMount...
Read morePlease download devcon.exe from Microsoft, then please refer to the following instructions:PM9000 RS-232: (1.) Devcon.exe disable SERENUMDCO9000 (To disable the touch screen) (2.) Devcon.exe enable SERENUMDCO9000...
Read more1. You may use editions prior to and including PenMount Windows Universal Driver V2.2.0.263 for installation. 2. If you use PenMount Windows Universal Driver V2.2.0.283, please modify the install.ini as follows...
Read moreIn Windows Server 2008, the PenMount device operates as a touch digitizer by default. However, touch digitizers can only operate when an extra feature called the "Desktop Experience" is installed. The "Desktop...
Read moreThe architecture of ARM or MIPS is RISC (Reduced Instruction Set Computing). Please contact our sales staff. We will provide you with PenMount's Linux kernel driver source code for you to drive your PenMount...
Read moreNo. WinCE does not support two or more devices. Linux can only support one PenMount device. If you have a special requirement for two PenMount devices, please contact our sales staff.
Read moreYes. We can provide an instructions manual to help you set up multiple monitors.
Read moreAfter the driver is installed, please perform calibration first to make sure the cursor works accurately.
Read moreRS-232 Cable: About 12 meters. USB Cable: About 3 meters.
Read morePenMount resistive touch controllers coupled with an appropriate mechanical design can meet IEC61000-4-2 ESD testing standards: Air Discharge 15KV, and Contact Discharge 8KV.
Read morePlease contact our sales window. We will provide you with a "Hardware Application Guide" which includes relevant specifications, reference circuit diagrams, and a byte order mark (BOM) table to expedite...
Read moreThe PenMount 6000/ 6010 series offers the latest models of resistive touch controllers. PenMount 6000/ 6010 controllers operate more smoothly and support USB and RS-232 interfaces.The PenMount 9000 series...
Read moreThe PenMount 6000 /6010/ 9000 series support 4 / 5 / 8-wire resistive touchscreens. (1.) PenMount 6000/ 6010 controllers support 4 / 5 / 8-wire resistive touchscreens and RS-232 or USB interfaces. (2.)...
Read more